Walker EmissionsTenneco’s Walker Emissions Control brand is helping automotive service providers simplify emissions control diagnosis and repair through a variety of new educational tools, including a recommended set of five checks to perform before installing a replacement catalytic converter. These diagnostic checks are covered in a free technical video available through the “TennecoInc” channel at YouTube.com.

“Our five diagnostic checks are designed to help shops eliminate comebacks by identifying and correcting issues that might have damaged the original converter and could quickly cause a replacement converter to fail as well,” said Joe Bacarella, manager, Technical Assistance Call Centers, North America Aftermarket, Tenneco. “These checks should be a formal part of every emissions system diagnosis.”

The Walker brand’s recommended five emissions system checks are:

1. Retrieve all powertrain control module (PCM) trouble codes and perform corresponding repairs. As part of this process, Tenneco also recommends checking for and performing any available PCM emissions-related reflash updates before installing a new converter.

2. Eliminate all exhaust system leaks. Leaks as small as a pinhole could introduce excess oxygen into the exhaust stream, triggering a P0420 code. Be particularly careful to check for leaks both upstream and within 18 inches downstream of the converter. Leaks can be identified through the use of a smoke machine, by performing a thorough visual inspection or pressurizing the system with compressed air.

3. Confirm the engine is in proper fuel control. An air/fuel mixture that is slightly rich or lean can trigger a trouble code and cause converter damage. This check can be performed with a four- or five-gas analyzer, many modern scan tools or a high-impedance digital Volt-Ohm meter. If using a gas analyzer, the Lambda reading should not fall outside a range of 0.995 to 1.005 and the hydrocarbon reading should be between zero and 35 parts per million.

4. Identify and correct any engine-related issues that could lead to converter contamination. Begin by performing a cooling system pressure check, which can indicate whether coolant could be leaking into the combustion chamber. When conducting this test, the system should hold the specified cap pressure for at least 15 minutes. Also check for excessive oil consumption by testing the overall mechanical condition of the engine. This can be assessed through a simple volumetric efficiency test.

5. Be sure you have the correct converter for the vehicle. Double check the vehicle’s year, make, model, engine and emissions certification, then select the corresponding EPA-compliant converter listed in your Walker Ultra Catalytic Converter catalog. If your shop is located in a state that follows California Air Resources Board (CARB) standards, you must also check the EFN (engine family number), sometimes referred to as “group number,” before selecting the appropriate CARB-compliant converter from the Walker CalCat® Catalytic Converter catalog.

“A vast majority of emissions service comebacks are avoidable, and by following these steps shops can dramatically increase the likelihood of eliminating all issues the first time,” Bacarella said. “It’s important to remember that catalytic converters rarely, if ever, fail on their own. This new process will protect the replacement converter from contamination and other damage, which will lead to long, trouble-free service for the shop and consumer.”

For more information regarding Walker Emissions Control components, contact your local parts and/or service provider, visit the Tenneco booth (No. 1626) at this week’s AAPEX Show in Las Vegas, or log on to www.walkerexhaust.com. Go to www.walkerexhaust.com to locate the nearest Walker parts and/or service provider.

You May Also Like

BendPak Founder Don Henthorn Passes Away

Grew company from small machine shop to global leader in car lifts and garage equipment.

Don Henthorn, owner and founder of BendPak Inc., peacefully passed away at home Thursday, March 28, at the age of 85. Under his leadership, BendPak has grown from a small machine shop to one of the world’s leading manufacturers of car lifts and automotive service equipment.

Management and operations of the privately owned company are unchanged. 

ASE Practice Tests Available Online

You can get a good idea of what to expect by adding the official ASE practice tests to your study plans.

AACF Celebrates 65 Years Serving the Aftermarket

AACF will be announcing more details about this commemorative fundraiser April 1st.

Bendix Releases Technical Materials for ADAS Support

They are designed to help technicians properly set up, inspect, and diagnose several components integrated with ADAS.

Dayco Adds Almost 30 Part Numbers in March

The 29 new part numbers will be available by the end of March for distributors interested in adding to their product coverage.

Other Posts

ASE Designates June as Automotive Service Professionals Month

ASE urges industry members to embrace Automotive Service Professionals Month as a platform for expressing gratitude.

ZF Aftermarket Releases 80 New Parts

The latest additions expand coverage to more than 5 million vehicles in operation.

Vehlo Acquires Shop Management Software, Shop-Ware

Shop-Ware is a cloud-based shop management platform catering to independent automotive aftermarket repair shops.

Auto Care Association Launches REPAIR Act Video

The goal is to emphasize the need for federal REPAIR Act legislation, according to the Auto Care Association.