Volkswagen Tech Tip: ATF Seeping from Final Drive Breather – UnderhoodService

Volkswagen Tech Tip: ATF Seeping from Final Drive Breather

ATF fluid may seep from the final drive breather vent on any Volkswagen model with a four-speed automatic transmission (AG4). To correct this problem, remove the final drive cover, drain the ATF and reinstall the cover. Refill the final drive with ....

ATF fluid may seep from the final drive breather vent on any model with a four-speed automatic transmission (AG4).

Affected Vehicles:

  • Beginning Aug. 26, 1996, transmission final drive units were filled with final drive oil P/N G 052 145 S2.
  • From Dec. 21, 1994, to August 25, 1996, automatic transmission final drive units were filled with VW ATF.

On final drive units filled with ATF, ATF may seep out of the final drive breather vent. See Arrow A, Fig. 1. Only transmissions within the build date range 21124 to 25086 (day, month and year) are affected. See Arrow B, Fig. 1.

Service Procedure:

  1. Remove the final drive cover, drain the ATF and reinstall the cover (always use a new gasket).
  2. Refill the final drive with P/N G 052 145 S2 final drive oil (see appropriate repair manual).

Note: Do not mix ATF and P/N G 052 145 S2 oil. If the final drive fluid must be replaced, use only P/N G 052 145 S2 011. You may top off final drive fluid with ATF, only if the final drive is filled with ATF and no fluid is coming out of the breather vent.

Technical service bulletin courtesy of Mitchell 1.

For additional information, visit www.mitchell1.com.

You May Also Like

Belts and Pulley Alignment

A misalignment of the plane of the belt can occur when a pulley is not parallel to the other pulleys on the belt drive system.

Drive Belt Alignment Alignment is key to the health of an engine belt. The belt drive system is designed to create friction between the grooves on the belt and pulley to transfer power from the crankshaft to the alternator, water pump or power steering pump. If the grooves on the belt do not align with the pulleys, the friction won’t be evenly applied and can result in wear and noise.

Diagnosing Misfires

What if there are no codes and a misfire is intermittent? This is where it gets complicated.

Lifter Deactivation

The area of contact between the lifters and cam lobes is the highest loaded surface inside an engine.

Alternator Testing For No Charge Conditions

Many alternator problems turn out to be nothing more than a bad connection at the alternator or a bad wiring harness.

Understanding Coolants

All-season coolant used inorganic acid technology and worked great for almost 30 years.

Other Posts

Ignition System Do’s and Don’ts

Why do ignition systems give technicians problems when diagnosing ignition-related misfires? The answer is that some technicians use tests that might give inconclusive results or do damage to the coil or drivers inside a module.

Tools To Service Serpentine Belts

Servicing the serpentine belt on some vehicles is a tough task.

Battery Charging and Diagnostics

Here are six tips to use when diagnosing a vehicle with a dead battery. 

Why Do Timing Chains Stretch?

As the timing chain wears, it can change the timing of the camshaft and crankshaft.