Tech Tip: Subaru Impreza With DTCs P0705, P0851, P2746, P2750 And/Or No Crank, No Start – UnderhoodService

Tech Tip: Subaru Impreza With DTCs P0705, P0851, P2746, P2750 And/Or No Crank, No Start

If you receive a customer concern of a Check Engine light, AT Temp light or a no engine-crank condition, the wiring harnesses to the transmission range sensor (inhibitor switch) should be closely inspected for damage or a short circuit to the CVT transmission case. In addition, Slow-Blow Fuse (SBF)-6 in the Main Fuse Box (M/B) may also have failed.

If you receive a customer concern of a Check Engine light, AT Temp light or a no engine-crank condition, the wiring harnesses to the transmission range sensor (inhibitor switch) should be closely inspected for damage or a short circuit to the CVT transmission case. In addition, Slow-Blow Fuse (SBF)-6 in the Main Fuse Box (M/B) may also have failed.

The new-style inhibitor harness assembly was incorporated into CVT production starting with transmission #048056 in the following vehicles.

Model            VIN
4-Door            C*025294
5-Door            C*233297  

Harness Assembly Inhibitor: New Part #: 31911AA041; Old Part #: 31911AA040

Service Procedure:

fig. 11. If any of the above DTCs are stored in memory, inspect the harnesses closely for damage or chaffing in the areas shown in Fig. 1. If no harness damage is found, diagnose each DTC per the appropriate service manual.

2. If DTC P2746 or P2750 is stored in memory at the same time, the freeze-frame data shows vehicle speed (VSP) to be “0” and the service manual troubleshooting results do not indicate a current fault is present, check to see if the inhibitor switch wiring harness is out of position as shown in Fig. 2.

fig. 2Another possible cause is application of the accelerator before full engagement of the CVT is complete. This can occur when shifting between N and D, N and R or P and R, combined with an extended pause between selecting of these ranges and might be confirmed during a road test with the customer. TCM reprogramming will be available in the future for this condition, but, until then, suggest avoiding the described driving pattern.

3. If DTC P2746 and P2750 are stored in memory at the same time, review your findings with the customer and try to determine exactly when the CEL illuminated. Ask if there were any driveability issues or operational concerns with the CVT, such as unusual shift shock or possibly a harsh engagement when shifting into gear. If you are not familiar with normal CVT operating characteristics, it’s recommended you compare with a like vehicle before ­proceeding. If you confirm a driveability concern as described, and ruled out any normal CVT characteristics, there may be a concern with the control valve body. In this case, replace it and then perform the Learning Control procedure to complete the repair.

Fig. 3Any damaged wiring harness must be replaced following the procedures listed in the service manual and routed as shown in Fig. 3. If the casting reinforcement bars of the transmission case are found to have sharp edges, carefully smooth them out using a file prior to installation of the replacement harness.

The revised harness and retaining clip position have been incorporated into production and replacement parts to provide additional clearance between the protective outer covering and the transmission case.

Courtesy of Identifix

You May Also Like

Understanding Coolants

All-season coolant used inorganic acid technology and worked great for almost 30 years.

In the 1960s, coolant was changed twice a year. In the fall, antifreeze with ethylene glycol-based coolant was put into the engine to prevent the coolant from freezing and cracking the block when a cold front hit. Often, if the engine got hot, the antifreeze would boil off. In the spring, the engine would be drained and filled with water and maybe a small can of an anti-corrosion treatment.

Ignition System Do’s and Don’ts

Why do ignition systems give technicians problems when diagnosing ignition-related misfires? The answer is that some technicians use tests that might give inconclusive results or do damage to the coil or drivers inside a module.

Tools To Service Serpentine Belts

Servicing the serpentine belt on some vehicles is a tough task.

Battery Charging and Diagnostics

Here are six tips to use when diagnosing a vehicle with a dead battery. 

Why Do Timing Chains Stretch?

As the timing chain wears, it can change the timing of the camshaft and crankshaft.

Other Posts

Carbon Deposits and Direct Injection Engines

The primary cause of these problems is that fuel and added detergents are not hitting the back of the intake valves.

Acura Turbo Engine Service

It is important to check the operation of the solenoids that control vacuum to the actuators.

Subaru EJ25 Head Gasket Problems

Most of the EJ head gasket failures occur around the 100,000-mile mark and start as a slow oil or coolant leak.

New Oil Specifications

Many 0W16 oils have a new donut certification mark on the bottle called API SN-PLUS and SN-PLUS Resource Conserving.