Tech Tip: Mercedes-Benz A/C Off Light Illuminated, A/C Not Functioning – UnderhoodService

Tech Tip: Mercedes-Benz A/C Off Light Illuminated, A/C Not Functioning

If you receive customer reports in the above models that the A/C Off light is illuminated and cannot be switched off and the air conditioning is not functional, the Refrigerant Level Temperature Pressure Sensor coding in the AAC unit may need to be set to "INACTIVE." Follow the below procedure to remedy a specification parameter in the refrigerant level logic circuit.

If you receive customer reports in the above models that the A/C Off light is illuminated and cannot be switched off and the air conditioning is not functional, the Refrigerant Level Temperature Pressure Sensor coding in the AAC unit may need to be set to “INACTIVE.” Follow the below procedure to remedy a specification parameter in the refrigerant level logic circuit.

Note: Replacement of the evaporator sensor or the operating unit is not necessary.

Note: Verify that the A/C system is not leaking and is not losing refrigerant.

Models 203, 209, 220 (up to August 2002 production) and 230 (up to August 2003 production)

1. Using STAR Diagnosis, enter the following menus: [Control Units > Air Conditioning > AAC control unit > Actual Values > A/C Control].

2. Observe the value for sensor (B12) Refrigerant Pressure Sensor.

3. Ensure the value for B12 is within specification.

4. Using STAR Diagnosis, enter the following menus: [Control Units > Body > EIS > Control Unit Adaptations > Read Coding and Change if Necessary > Climate Control >Refrigerant Level Check].

5. Set the coding for Refrigerant Level Check ­“INACTIVE.”

6. Select F3 and transfer coding to the control unit.

7. Remove STAR Diagnosis and verify that the A/C Off light is not illuminated by default and will turn on/off after pressing of the A/C Off switch.

Model 211

1. Using STAR Diagnosis, enter the following menus: [Control Units > Air Conditioning > AAC control unit > Actual Values > A/C Control].

2. Observe the value for sensor B12/2 Refrigerant Level Pressure and Temperature Sensor.

3. Ensure the value for B12/2 is within the Specified Value range.

4. Using STAR Diagnosis, enter the following menus: [AAC > Control Unit Adaptations > Read Codings and Change if Necessary > Workshop ­Coding].

5. Set the coding for Coolant level check via pressure and temperature sensor (“Maximum principle”) to “INACTIVE.”

6. Select F3 and transfer coding to the control unit.

7. Remove STAR Diagnosis and verify that the A/C Off light is not illuminated by default and will turn on/off after pressing of the A/C Off switch.

Model 215, 220 (as of September 2002) and 230 (as of September 2003)

1. Using STAR Diagnosis, enter the following menus: [Control Units > Air Conditioning > AAC control unit > Actual Values > Temperature Sensor].

2. Observe the value for sensor (B12) Refrigerant Pressure Sensor.

3. Ensure the value for B12 is within specification.

4. Using STAR Diagnosis, enter the following menus: [Control Units > Body > CGW > Control Unit Adaptations > Read Coding and Change if Necessary > Climate Control > Refrigerant Level Check].

5. Set the coding for Refrigerant Level Check ­“INACTIVE.”

6. Select F3 and transfer coding to the control unit.

7. Remove STAR Diagnosis and verify that the A/C Off light is not illuminated by default and will turn on/off after pressing of the A/C Off switch.

Courtesy of Mercedes-Benz USA, LLC.

You May Also Like

Nearly 5,000 To Participate In Auto Value, Bumper To Bumper ‘Festive Walk’ To AAPEX 2018

On Thursday, Nov. 1, nearly 5,000 Auto Value and Bumper to Bumper automotive professionals wearing matching yellow shirts will begin their “festive walk” from the Mirage hotel to AAPEX 2018 at the Sands Expo, temporarily shutting down the busy Las Vegas Boulevard along the way.

On Thursday, Nov. 1, nearly 5,000 Auto Value and Bumper to Bumper automotive professionals wearing matching yellow shirts will begin their “festive walk” from the Mirage hotel to AAPEX 2018 at the Sands Expo, temporarily shutting down the busy Las Vegas Boulevard along the way.

The group is scheduled to depart at approximately 8:30 a.m. (PDT) and start arriving at AAPEX for their day-long visit around 9 a.m. The group will include parts store operators, shop owners, technicians and service writers who are part of the Aftermarket Auto Parts Alliance. Las Vegas showgirls and a marching band will join in the festivities as the group makes its way to AAPEX.

Drive Belt Checklist: What Are You Missing?

You might have only one chance to sell a customer a new serpentine belt. With belts lasting roughly 90,000 miles, proper inspection at the time of failure is critical not only for selling the belt, but also for ensuring add-on sales and better customer satisfaction.

3 Reasons To Replace Cabin Air Filters In Winter

Often driven by an “out of sight, out of mind” mentality, most consumers don’t think about purchasing cabin air filters. That’s why educating consumers on the benefits of cabin air filters can be a shop’s best sales pitch for selling these maintenance add-ons.

VIDEO: Using Airflow To Sell Cabin Air Filters

Andrew Markel introduces an inexpensive tool that can assist in selling cabin air filter replacements. Sponsored by Auto Value and Bumper to Bumper.

airflow-selling-cabin-air-filter-video-featured
Air Conditioning Odor Causes

Air conditioning odors typically result from the uncontrolled growth of bacteria and other microorganisms in the evaporator. Research by independent laboratories has found fungi such as Aspergillus, Cladesporium, Penicillium and others growing on cooling coils and other A/C system areas.

ac air conditioning smells featured

Other Posts

Rotary Announces New A/C Recharging Equipment Line

Through its partnership with TEXA, Rotary will launch three new models in the spring of 2023.

Dorman Launches 300+ New Products In November

Among the new products is an OE FIX climate control module designed to fit 1.7M Chevrolet Express & GMC Savana vehicles.

Curing Springtime Air Conditioning Smells

Air conditioning scents can come from a host of things.

Never Flush A Parallel-Flow A/C Condenser (VIDEO)

Today’s condensers are efficient and vulnerable for the same reason. Sponsored by The Group Training Academy.