Diagnostic Solutions: Starter And Battery Diagnostics

Diagnostic Solutions: Starter And Battery Diagnostics

On June 15, 1911, Charles F. Kettering was awarded a patent for an electric self-starter for automobile engines.

In the early days of the automotive industry, starting a car used to be a dangerous process that involved multiple steps, physical strength and a danger of getting knocked out by the cranking mechanism.

On June 15, 1911, Charles F. Kettering was awarded a patent for an electric self-starter for automobile engines. Thinking out of the box, Kettering designed a small, high-torque motor that would deliver a burst of energy lasting only long enough to initiate the internal combustion cycle. Fortunately for modern commuters, Kettering’s electric self-starter transformed the automobile from a temperamental novelty item into a practical means of transportation.

COMPONENT BASICS

From a historical view, it’s important to remember that Kettering’s conventional field-coil starter required battery power to create the magnetic field needed to make the starter armature turn. During the 1980s, field-coil starters were phased out in favor of “ferrite” permanent-magnet starters.

Since the fields in permanent magnet starters don’t require battery power, permanent-magnet starters require much less current to crank an engine. The result is a much lighter, far more efficient starter motor. But, because permanent or “ferrite” magnets are made of a brittle ceramic material, they are vulnerable to cracking caused by sudden impacts. Cracked magnets can be tough to diagnose, which is why it’s usually better to replace the starter as an assembly than to repair or rebuild it. See Photo 1.

Photo 1: The insulation between the commutator segments should be recessed about 1/32″ beneath the commutator bars.

In addition, the rotating mass of the starter armature is reduced to create a more compact starter motor assembly. As pictured in Photo 2, the armature on most modern starters terminates into a sun gear mating with a set of planetary gears (see Photo 3) provide the initial gear reduction for the starter. A secondary reduction gear can also be used on starters like the one used to illustrate this story. See Photo 4.

Photo 2: In this application, the starter armature is surrounded by six permanent magnets.
Photo 3: This starter motor terminates into a planetary gear set similar to those used in automatic transmissions.
Photo 4: The secondary reduction drive gear contains an over-run clutch that disengages the starter motor as the engine speed increases.

The starter “solenoid” is actually a combination of an electric relay and solenoid. The relay portion electrically connects the starter armature to the battery. The solenoid portion mechanically engages the starter’s drive pinion with the engine’s flywheel gear. While modern solenoids usually incorporate two high-amperage terminals and one low-amperage, primary activation terminal, some older designs might incorporate an additional primary “bypass” terminal that was originally designed to boost ignition coil voltage during cranking. In some applications, the bypass terminal is unused and remains a vestigial remnant of past technology.

The starter over-run or one-way clutch is a simple roller-type clutch that’s designed to release when the engine speed exceeds cranking speed. In rare instances, the clutch will seize, which can cause the starter armature to explode from centrifugal force as the engine accelerates. In other cases, the clutch will simply wear out, which usually results in a “whirring” sound, indicating that the starter motor is running, but not engaged to the flywheel.

STARTER ACTUATION SYSTEMS

For safety’s sake, the starter’s primary circuit is routed through a neutral safety switch on automatic transmission vehicles and through a clutch safety switch on manual transmission models. With that said, current practice is to reduce the electrical load on the ignition, neutral safety and clutch switches by inserting a starter relay into the starter primary circuit. In this case, the above switches activate the starter relay switch rather than the starter’s primary solenoid circuit.

Keep in mind also that modern technology in some vehicles has delegated the starter engagement process to the Powertrain Control Module (PCM). In this system, turning the ignition switch or pressing the “start” button simply commands the PCM to engage the starter motor. Failures in these systems should first be diagnosed with a scan tool and by using diagnostic techniques similar to those used in any other system controlled by the PCM.

BATTERY DIAGNOSTICS

The first step is to make sure that the battery terminals and cables are free of corrosion. Next, determine the battery state of charge (SOC) and condition by testing with a conductance or variable-load, carbon pile battery tester. Recharge or replace the battery as required. Voltage drop from the battery to the starter can be measured by attaching a voltmeter in parallel to the positive battery terminal and to the solenoid B+ terminal.

The rule of thumb is that voltage drop shouldn’t exceed 0.5 volts during cranking. The voltage drop on the negative ground terminal can similarly be measured by attaching the voltmeter lead to a clean area on the engine block and to the battery B- terminal. Here again, the voltage drop shouldn’t exceed 0.5 volts. See Photo 5.

Photo 5: Corrosion at the lower solenoid terminal on this starter caused an intermittent “clicking,” no-cranking complaint.

STARTER CURRENT DIAGNOSIS

Most starter-related electrical failures can be diagnosed by measuring current flow into the starter. Actual current flow to the starter can be measured by attaching a 600-amp inductive current probe to the battery positive or negative cables. The probe can be attached to a multimeter with a minimum/maximum (min/max) recording feature or to a two-channel lab scope. To illustrate how a starter works on a vehicle in good condition, I’ve included a lab scope recording of battery terminal voltage and starter amperage draw. See Figure 1.

Figure 1: A lab scope display of the relationship between voltage and amperage can provide valuable information about the condition of the starter and battery.

The amperage draw begins from the “zero” point at the left. The initial amperage drawn by the solenoid primary circuit occurs at 70 milliseconds (ms). If the voltage remains at zero, it’s likely that the system has a bad neutral or clutch safety switch, or that the starter relay is defective. If the solenoid amperage remains at 2-3 amps, the solenoid doesn’t have continuity to the starter. Bad solenoid contacts, worn starter brushes or an open-circuit armature can be the cause. In this case, the primary symptom will be a clicking noise as the solenoid primary circuit activates. Any of the above failures can result in an intermittent starter engagement complaint.

Once the solenoid closes the circuit at 100 ms, the amperage draw increases to 311 amperes at the trigger point. As the engine cranks, the amperage draw declines until approximately 300 ms. At about 300 ms, amperage rises slightly as the torque load on the starter is momentarily increased due to a possible variation in fuel delivery or spark advance.

Similarly, battery terminal voltage spikes down to nearly 8.0 volts at 100 ms as cranking amperage is suddenly drawn from the battery. The battery terminal voltage begins to rise to about 10.0 volts at 200 ms as the starter amperage begins to stabilize. As the engine begins to crank, 10.0 volts should be considered the minimum voltage. If the battery won’t maintain 10.0 volts during cranking, the PCM might fail to process data or activate the injector and ignition system drivers. See Figure 2.

Figure 2: At 2.5 milliseconds, available battery voltage drops from about 13.0 volts to 9.19 volts as the starter is engaged. After the engine starts at 6.3 milliseconds, the alternator begins recharging the battery at 13.8 volts.

BATTERY VOLTAGE GRAPHING

Graphing available battery terminal voltage also provides a direct insight into battery condition. Charging voltage should be achieved approximately two seconds after the engine starts. If charging voltage doesn’t increase within that time interval, it’s likely that the battery doesn’t have enough remaining plate capacity to fully support starter current draw. In any case, using a lab scope to display available battery voltage and amperage discharge is an easy way to quickly evaluate battery, starter and starter activation systems. 

You May Also Like

Chrysler’s Totally Integrated Power Module

The TIPM is on the CAN bus, any issues with the communication between the ECM, ABS and BCM can cause problems with the TIPM.

TIPM is a fuse box, relay box and electronic module all in one. The electronic module is connected to several data networks.  For engineers, the module reduces a lot of wiring under the hood and passing through the firewall. The TIPM also increases the functionality of a component by allowing several inputs to control one component. 

Mercedes EQS Service Opportunities

EQ is the EV brand for Mercedes. It is the equivalent of Audi’s Etron or VW’s iD brands.

ADAS Calibration Tips

Here are 10 tips to follow during ADAS Calibration.

Chassis Control Modules After Reconnecting Battery

To resolve the issue, fully disconnect the negative lead from the battery terminal.

Reflashing Power Supplies

A power supply to keep the system voltage consistent is a required piece of equipment to perform a reflash procedure.

Other Posts

Alternator Testing For No Charge Conditions

Many alternator problems turn out to be nothing more than a bad connection at the alternator or a bad wiring harness.

BMW Transfer Case Service

The transfer case is a rather unique design in the way that it operates a clutch pack mechanically, not hydraulically.

Today’s Fuel Pressure Diagnostics

Direct injection pressure is measured with sensors, and you’ll need a scan tool to measure the signals

OBDII Connectors

OBDII connectors serve as the main communication point between the technician and the vehicle.