When I was a kid, I saw a movie called “Juggernaut” with Richard Harris as the
main character. It was about a cruise liner that was about to blow up because a
terrorist had planted 55-gallon drum bombs all over the ship. The premise of
the story line is that Harris was going to save all the people on the ship by
defusing the bombs. All through the movie, there were references to the
different relays and electrical circuits.
I would have to say, without a doubt, this is where my long-time involvement
with electricity started. It’s where I learned the difference between an N.O.
and an N.C. relay, and a few other electrical terms and techniques. (Watch the
movie and see if you can spot the N.C. relay.)
What does this have to do with diagnosing today’s cars? Plenty. I call it
“playing bomb,” just like in the movie when Harris asks, “Cut the red wire or
the blue wire?” I use the same method when I’m diagnosing hard-to-find
electrical shorts.
Here’s an example: 2002 Hyundai Sonata 2.7L with a no- start condition and the
ECU/EGR fuse blows as soon as you turn on the key. There’s no spark, no fuel
pump, no injector signal and no service light.
Coding the car wasn’t an option. For one thing, the fuse that kept blowing also
powered up the ECU. So there weren’t any codes that could be read because the
ECU wasn’t responding. The big issue was how to find the short that was causing
the problem.
Looking at the wiring diagrams just made it worse. There were seven different
components tied to the same fuse from the top of the motor to the bottom, and
from the trunk to the front of the engine. I guess you could have disconnected
each and every one of the components. That would have been time-consuming for
sure, but helpful only if the short was from the connector to the component,
and not the entire wiring harness.
At this point, you don’t have a clue as to what component or at which part of
the car the problem is originating, so how do you narrow down the problem into
smaller sections, that you then can narrow down even further? My method was to
find a spot from which all of these components get their positive voltage. The
obvious spot was the fuse box.
I turned the fuse box over and removed the protective cover to expose the
wires. With the battery still hooked up and the fuse removed, I used a standard
test light with the end hooked to the positive post of the battery, and probed
each of the wires in the circuit with the light. If I came across the correct
“grounded” lead, the test light would light up, showing that it was the circuit
that was grounded.
The leads on the back of the fuse box were in pairs, two to each terminal on
the back of the fuse box. After a few tries, I found the pair that was
grounded. Now I had to separate the two remaining wires, and get it down to one
lead. This is where playing bomb comes in…which one do I cut? In this case,
they are both the same color, so which one? Leaving the test light connected, I
cut one of the wires…BOOM…and the light went off. I guess I know which lead to
check now.
With this one lead out of the way, I could put a fuse back into the fuse box,
and see if all the other systems came back on. They sure enough did. But, I
still don’t know which of the seven different components this particular lead
went to.
The next thing to do was to try to start it with this one lead cut. Of course,
I wasn’t expecting it to start, but what I was hoping for was a code and, if
this particular lead wasn’t the direct voltage to the ECU, I should get
something P0335 or crank sensor circuit. So far, so good; time to locate and
go directly to the crank sensor and disconnect it.
With the sensor disconnected, I could then reattach the lead that I just cut
and see if it was still shorted. It wasn’t, so the problem had to be between
the connector and the crank sensor itself. Sure enough, the three leads of the
sensor had all of their insulation rotted off and the three wires were all
tangled together.
I replaced the crank sensor, repaired the wire I cut and reinstalled the fuse
box, finishing the job up in record time.
Oh, and by the way, this car was at another shop for four days and no one could
find this problem. All said and done, I spent about 30 minutes diagnosing it.
Playing bomb is a fast and effective way of finding these types of problems.
This method works well when you have multiple wires on the same circuit, and
can also be helpful when there are only two wires in the circuit.
The big question is, do you cut the blue one or the red one? Tick-tick,
tick-tick, BOOM!
Sidebar:
Hyundai Voltage Drop Diagnostics
Fuse Fiasco
More than one OEM has sent out a TSB or internal memos warning dealerships that
some discount, no-name blade-style fuses can lead to damage to a vehicle’s
electrical system. Even the National Highway and Traffic Safety Administration
in 2007 investigated the problem due to some vehicle fires.
300,000 sets containing up to 120 fuses were sold to the public. This means as
many as 35 million fuses are waiting for you to find them in your customers’
vehicles. The fuses are supposed to be 5-30 amps, but may have been made with
the wrong amperages. The housings are prone to melting because the fuse is made
of aluminum instead of zinc, and the housing material is not high-temperature
resistant.
If you get a vehicle in your shop with electrical problems like blown fuses or
damaged wiring, ask the customer if he/she replaced any fuses on their own. The
fuses can come from a variety of sources. But, most of the fuses were sold at
retail tool stores and some auto parts stores. It’s difficult to tell the
defective fuses from high-quality fuses. Knowing if the customer replaced a
fuse can help you rule out a diagnostic problem.
About the Author
Scott “Gonzo” Weaver
Gonzosae@aol.com
Scott “Gonzo” Weaver is the owner of Superior Auto Electric in Tulsa, Okla. and has owned the shop for 27 years. He was given his trademark nickname “Gonzo” while serving in the USMC. He is the author of the book “Hey Look! I Found the Loose Nut”, that can be purchased online at Amazon.com or at www.gonzostoolbox.com.
More Articles in Electrical